ORDERING INFORMATION
Power Luminaire Code
1 x 8W T5 230/240VAC 3hr Non-maintained fitting c/w gear, battery & lamp FDES1083N
1 x 8W T5 127VAC 3hr Non-maintained fitting c/w gear, battery & lamp FDES1082N
1 x 8W T5 110VAC 3hr Non-maintained fitting c/w gear, battery & lamp FDES1081N
1 x 8W T5 230/240VAC 3hr Maintained fitting c/w gear, battery & lamp FDES1084M
1 x 8W T5 127VAC 3hr Maintained fitting c/w gear, battery & lamp FDES1082M
1 x 8W T5 110VAC 3hr Maintained fitting c/w gear, battery & lamp FDES1081M
2 x 8W T5 230/240VAC 3hr Sustained fitting c/w gear, battery & lamps FDES2084S

FDES Series

Self-contained emergency fluorescent flameproof luminaires

Application

A range of cylindrical fluorescent emergency luminaires for use in hazardous locations as well as areas exposed to dirt, water, moisture and corrosive conditions. They are available in a choice of lamp numbers, in maintained and non-maintained format and with emergency battery back-up. Suitable for use in oil refineries, petrochemical facilities, pulp and paper mills, spray booths, sewage and water treatment facilities and tunnels where emergency lighting is required.

General Description

IP66/IP68  230 Volts 50Hz - Nominal supply
Impact resistant toughened glass sealed diffuser
Supplied with O ring for improved ingress protection
Operates in any position, 3 hour duration
ATEX/IEDEx zone 1 and 2-21 and 2-22:  Ex II 2 GD
Charge indicator by 1 red LED (lifetime over 10 years)

Other information

Constructed from an impact resistant toughened glass sealed diffuser, secured by cast endcaps and rigid fastenings. Suitable for use in oil refineries, petrochemical facilities, pulp and paper mills, spray booths, sewage and water treatment facilities and tunnels where emergency lighting is required. Against electric shock Class 1 protected with earthed metalwork. Against ingress of dust and moisture IP68 Technical Specification. The FDES Series range of luminaires is designed and manufactured to meet the requirements of BSEN 60598 2-1 and ATEX/IEDEx zone 1 and 2-21 and 2-22.

Specification

A range of cylindrical fluorescent luminaires for use in hazardous locations as well as areas exposed to dirt, water, moisture and corrosive conditions. Constructed from an impact resistant toughened glass sealed diffuser, secured by cast endcaps and rigid fastenings. Suitable for use in oil refineries, petrochemical facilities, pulp and paper mills, spray booths, sewage and water treatment facilities and tunnels where emergency lighting is required.